Diesel Engines
|
Cylinder Misfiring
|
0.5 X |
radial, tangential |
5 mils |
narrow band |
No diagnostics can be done until all misfiring is corrected |
|
Imbalance, Misalignment Torque Reaction, Weak Foundation |
1X |
radial, tangential |
5 mils |
narrow band |
1X and No. of firing strokes per revolution are caused by torque reaction, which in turn can cause misalignment |
|
Harmonic Balancer |
2X |
radial, tangential |
4 mils |
narrow band |
Correct by rotating the balancer |
|
Cylinder Combustion Forces |
1.5X, 2.5X, etc |
radial, tangential |
4.3 mils |
narrow band |
Normal operating levels
|